Minimum Surface Casing Requirements


Minimum surface casing requirements for protecting fresh and usable water and to meet alternate #1 on Intent to Drill cards, Form C-1
S=Section, T=Township, R=Range


Stanton County

Set 20 feet into the Jurassic (where present) or Permian in all areas. The following options are open:

(a) set 20 feet into the Triassic or Permian or
(b) set through all unconsolidated material plus 20 feet into the underlying formation and cement the production string from a point 20 feet below the base of the Dakota or 20 feet below the base of the Cheyenne, if specifically designated, to the surface.

If (b) is used and the hole is dry, refer to K.A.R. 82-3-114. In all cases, set through all unconsolidated material plus 20 feet into the underlying formation.