Minimum Surface Casing Requirements


Minimum surface casing requirements for protecting fresh and usable water and to meet alternate #1 on Intent to Drill cards, Form C-1
S=Section, T=Township, R=Range


Thomas County

In all areas, protect through all unconsolidated material plus 50 feet into the underlying formation. In T.7-R.31W and T.7-R.32W and in T.9 and 10S, protect through the Dakota formation plus 50 feet into the underlying formation. The following options are open:

(a) set through the Dakota plus 50 feet into the underlying formation or
(b) set through all unconsolidated material plus 50 feet into the underlying formation and cement the production string from a point 50 feet below the base of the Dakota to the surface.

If (b) is used and the hole is dry, refer to K.A.R. 82-3-114.